Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Cobanoglu, N." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Bond Strength of Self-etch Adhesives After Saliva Contamination at Different Application Steps
    (OPERATIVE DENTISTRY INC, 2013) Cobanoglu, N.; Unlu, N.; Ozer, F. F.; Blatz, M. B.
    This study evaluated and compared the effect of saliva contamination and possible decontamination methods on bond strengths of two self-etching adhesive systems (Clearfil SE Bond [CSE], Optibond Solo Plus SE [OSE]). Flat occlusal dentin surfaces were created on 180 extracted human molar teeth. The two bonding systems and corresponding composite resins (Clearfil AP-X, Kerr Point 4) were bonded to the dentin under six surface conditions (n=15/group): group 1 (control): primer/bonding/composite; group 2: saliva/drying/primer/ bonding/composite; group 3: primer/saliva/ rinsing/drying/primer/bonding/composite; group 4: primer/saliva/rinsing/drying/bonding/ composite; group 5: primer/bonding (cured)/ saliva/rinsing/drying/primer/bonding/composite; group 6: primer/bonding (cured)/saliva/removing contaminated layer with a bur/rinsing/ drying/primer/bonding/composite. Shear bond strength was tested after specimens were stored in distilled water at 37 C for 24 hours. One-way analysis of variance and Tukey post hoc tests were used for statistical analyses. For CSE, groups 2, 3, and 4 and for OSE, groups 6, 2, and 4 showed significantly lower bond strengths than the control group (p<0.05). CSE groups 5 and 6 and OSE groups 3 and 5 revealed bond strengths similar to the control. When saliva contamination occurred after light polymerization of the bonding agent, repeating the bonding procedure recovered the bonding capacity of both self-etch adhesives. However, saliva contamination before or after primer application negatively affected their bond strength.
  • Küçük Resim Yok
    Öğe
    A Five-Year Clinical Evaluation of Direct Nanofilled and Indirect Composite Resin Restorations in Posterior Teeth
    (OPERATIVE DENTISTRY INC, 2013) Cetin, A. R.; Unlu, N.; Cobanoglu, N.
    Aim: To assess the clinical efficacy of posterior composite resin restorations placed directly and indirectly in posterior teeth after five years. Materials and Methods: A total of 108 cavities in 54 patients were restored with three direct composite resins (Filtek SupremeXT [FSXT], Tetric Evo Ceram [TEC], AELITE Aesthetic [AA]) and two indirect composite resins (Estenia [E] and Tescera ATL [TATL]). All restorations were evaluated by two examiners using the United States Public Health Service criteria at baseline and five years after placement. Statistical analysis was completed with Fisher exact and McNemar chi(2) tests. Results: At baseline, 4% (five) of the restored teeth presented postoperative sensitivity; however, only one of them (a member of the E group) required canal treatment and replacement after two years. At the five-year evaluation, all restorations were retained, with Alpha ratings at 100%. Only one tooth (in the TEC group) required replacement after three years due to secondary caries. Color match, surface texture, and marginal integrity were predominantly scored as Alpha after five years for all groups. After that time, marginal discoloration was scored as Alpha in 64% of AE restorations, 70% of TATL restorations, 73% of E restorations, and 87% of FSXT restorations. There were no Charlie scores recorded for any of the restorative systems. Conclusions: Under controlled clinical conditions, indirect composite resin inlays and direct composite resin restorations exhibited an annual failure rate of 2.5% and 1.6%, respectively, after five years. Therefore, the investigated materials showed acceptable clinical performance, and no significant differences were found among them.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim