Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Goek, Hasan" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Comparison of myocardial performance index obtained either by conventional echocardiography or tissue Doppler echocardiography in healthy subjects and patients with heart failure
    (SPRINGER, 2009) Duzenli, Mehmet Akif; Ozdemir, Kurtulus; Aygul, Nazif; Soylu, Ahmet; Aygul, Meryem Ulku; Goek, Hasan
    This study was planned to investigate the normal reference values of myocardial performance index (MPI) obtained by tissue Doppler echocardiography (TDE) and the agreement between MPI measured by TDE and conventional MPI measured by pulsed-wave Doppler (PWD) in healthy subjects and patients with heart failure (HF). Two hundred and three patients with HF and 190 healthy subjects were enrolled in this study. Isovolumic contraction and relaxation time (ICT and IRT) and ejection time (ET) were measured from mitral inflow and left ventricular (LV) outflow. Tissue Doppler echocardiography recordings were obtained at the septal, lateral, inferior, and anterior of the mitral annulus and same time intervals were measured. Myocardial performance index was calculated. The functional capacity of the patients with HF was determined according to New York Heart Association classification. TDE-MPI values were higher than conventional PWD-MPI values in both groups (53% +/- 8% vs 48% +/- 11%, P < 0.0001 in the healthy subjects; 84% +/- 21% vs 72% +/- 19%, P < 0.0001 in the patients with HF). Moderate agreement was found between PWD-MPI and LV mean TDE-MPI in both groups. In identifying patients with moderately or severely decreased LV ejection fraction, TDE-MPI had higher cutoff values than conventional PWD-MPI, and TDE-MPI had higher specificity, sensitivity, negative predictive value, and diagnostic accuracy. In patients with HF, TDE-MPI had a stronger correlation with LV ejection fraction and functional capacity than did PWD-MPI. TDE-MPI is an alternative to conventional PWD-MPI in assessment of cardiac function. However, the higher MPI cutoff points should be considered when this method is used for the evaluation of cardiac function.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim