Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Tercan, MA" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Three-dimensional contrast-enhanced magnetic resonance angiography (3-D CE-MRA) in the evaluation of hemodialysis access complications, and the condition of central veins in patients who are candidates for hemodialysis access
    (WICHTIG EDITORE, 2004) Paksoy, Y; Gormus, N; Tercan, MA
    Background: Arteriovenous (AV) fistulas are crucial in Patients requiring long-term hemodialysis (HD). Dysfunctions of these fistulas are the most common causes of recurrent hospitalizations. This study aimed to evaluate the feasibility, safety and usefulness of contrast-enhanced magnetic resonance angiography (CE-MRA) in the evaluation of HD fistulas complications, and the condition of the central veins before HD access. Methods: This study comprised 30 consecutive patients (15 females, 15 males; age range 25-66 yrs, mean +/- SD 51.2 +/- 9.9 yrs). Of 30 patients, 26 had native AV fistulas and the remaining four patients, who had a history of previous subclavian vein catheterization, were candidates for HD fistulas. Nine patients had a radiocephalic fistula, 15 had a brachiobasilic fistula, one had a saphenous vein graft, and one had brachiobasilic vein transposition. To observe the fistula complications in these cases, three-dimensional (3-D) CE-MRA using gadolinium was performed. Results: The results were considered normal in three patients (10%), who were candidates for AV fistula construction; one patient had central vein occlusion due to previous catheterization. Thirteen patients (43.3%) had venous stenosis or occlusion; three of them (10%) had low CE arteries distal to fistula region, leading to ischemic complications, and six (20%) had stenosis at the fistula region. Seven patients (23.3%) had venous pseudoaneurysms, whereas two of them had both pseudoaneurysms and fistula region stenosis, and one had both venous stenosis and pseudoaneurysm. There were no adverse or allergic-like reactions or heat and taste sensations observed in our series. Conclusions: 3-D CE-MRA is a useful, safe and a practical imaging modality in complicated fistula diagnosis with fewer complications and side-effects in comparison to fistulography.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim