Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Tholakanahalli, Venkatakrishna N." seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Proximity of Right Coronary Artery to Cavotricuspid Isthmus as Determined by Computed Tomography
    (Wiley-Blackwell, 2010) Al Aloul, Basel; Sigurdsson, Gardar; Can, İlknur; Li, Jian-Mingi; Dykoski, Richard; Tholakanahalli, Venkatakrishna N.
    Background: Radiofrequency ablation of atrial flutter is a commonly performed procedure. Ablation success depends upon complete transmural atrial tissue injury to achieve bidirectional cavotricuspid isthmus (CTI) block. Transmural ablation increases risk of injury to the adjacent right coronary artery (RCA). Distance between the RCA and the endocardium within the CTI area is not well described. We aimed to perform in vivo measurements of the distance between the CTI area and adjacent RCA. Methods: Thirty-three consecutive patients underwent electrocardiogram-gated contrast-enhanced computed tomography. CTI area was divided into nine segments based on three common catheter locations (paraseptal, central, and lateral or 5, 6, and 7 o'clock) and ventricular to atrial ablation line. Results: Mean age was 64 +/- 11 years and 97% of the participants were male. Paraseptal, central, and lateral measurements at the tricuspid annulus ridge showed endocardial to RCA distance 9 +/- 3, 6 +/- 2, and 5 +/- 3 mm, respectively (range 2-17 mm). Corresponding measurements for the ventricular side were 5 +/- 3, 4 +/- 2, and 4 +/- 2 mm and atrial side measurements were 3 +/- 2, 3 +/- 2, and 3 +/- 3 mm. Distance was < 2 mm in 14% of segments on the ventricular side and 39% of segments on the atrial side. Paired t-test showed significant difference (P < 0.001) between tricuspid annulus ridge measurements and adjacent atrial or ventricular measurements. Conclusions: Distance between endocardium and RCA lumen is reduced in areas adjacent to the tricuspid annulus ridge.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim