Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Ucgul, I." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet
    (ELSEVIER SCI LTD, 2009) Dincer, K.; Baskaya, S.; Uysal, B. Z.; Ucgul, I.
    In this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30 degrees-180 degrees) of a mobile plug, located at the hot outlet side in a Ranque-Hilsch Vortex Tube (RHVT), were determined experimentally for best performance. In addition to plug parameters, effects of supply pressure (200-420 kPa) and number of nozzles (2, 4, 6) were also studied. The internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations were studied. The maximum difference in the temperatures of hot and cold streams was obtained for the plug diameter of 5 mm, tip angles of 30 degrees and 60 degrees, 4 nozzles and by keeping the plug location at the far extreme end. (C) 2008 Elsevier Ltd and IIR. All rights reserved.
  • Küçük Resim Yok
    Öğe
    Fuzzy Modeling of Performance of Counterflow Ranque-Hilsch Vortex Tubes with Different Geometric Constructions
    (TAYLOR & FRANCIS INC, 2008) Dincer, K.; Tasdemir, S.; Baskaya, S.; Ucgul, I.; Uysal, B. Z.
    In this article, we present the development of a fuzzy expert system (FES) for fuzzy modeling of the performance of counterflow Ranque-Hilsch vortex tubes for different geometric constructions. Experimental values were obtained from a detailed experimental investigation. With these experimental values, FES models of the Ranque-Hilsch vortex tube behavior were designed using the MATLAB 6.5 fuzzy logic toolbox in Windows XP running on an Intel 3.0-Ghz PC. For this process P, N, , and L/D were chosen as input and Th, Tc, T as output parameters. FES results agree well with experimental data. It was found that the coefficient of multiple determination (R2 value) between the actual and fuzzy predicted data is Th=0.9801, the R2 value for Tc values is 0.9841, and the R2 value for T values is 0.9748.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim