Salicylate Ion-Selective Electrode Based on a Calix[4]arene as Ionophore
dc.contributor.author | Ayanoğlu, Melek Nur | |
dc.contributor.author | Erturun, H. Elif Kormali | |
dc.contributor.author | Özel, Ayça Demirel | |
dc.contributor.author | Şahin, Özlem | |
dc.contributor.author | Yılmaz, Mustafa | |
dc.contributor.author | Kılıç, Esma | |
dc.date.accessioned | 2020-03-26T19:06:59Z | |
dc.date.available | 2020-03-26T19:06:59Z | |
dc.date.issued | 2015 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | A salicylate-selective electrode based on calix[4]arene derivative was developed and its response characteristics were investigated. The optimum membrane composition was 1% ionophore, 30% PVC, 69% DOS. The electrode exhibited a Nernstian slope of 58.8 +/- 0.5mV/pSal in the range of 1.0x10(-5)-1.0x10(-1)M with a detection limit of 4.3x10(-6)M at pH4.0, 20 +/- 1 degrees C. The potentiometric response of the electrode in the presence of different anions was investigated by the separate solution method. The lifetime was found at least 4months, and its response time was 5-10s. It was successfully used for the potentiometric determination of salicylate in pharmaceutical preparations. | en_US |
dc.description.sponsorship | Ankara University Scientific Research Projects Coordination UnitAnkara University [13L4240007, 10B4240003] | en_US |
dc.description.sponsorship | This research has been supported by the Ankara University Scientific Research Projects Coordination Unit, Project No: 13L4240007 and Project No: 10B4240003. | en_US |
dc.identifier.doi | 10.1002/elan.201400737 | en_US |
dc.identifier.endpage | 1684 | en_US |
dc.identifier.issn | 1040-0397 | en_US |
dc.identifier.issn | 1521-4109 | en_US |
dc.identifier.issue | 7 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1676 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1002/elan.201400737 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/32526 | |
dc.identifier.volume | 27 | en_US |
dc.identifier.wos | WOS:000357408900018 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | WILEY-V C H VERLAG GMBH | en_US |
dc.relation.ispartof | ELECTROANALYSIS | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Salicylate-selective electrode | en_US |
dc.subject | Calix[4]arene | en_US |
dc.subject | Potentiometry | en_US |
dc.subject | Salicylate determination | en_US |
dc.title | Salicylate Ion-Selective Electrode Based on a Calix[4]arene as Ionophore | en_US |
dc.type | Article | en_US |