Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES

dc.contributor.authorMulazimoglu, A. Demir
dc.contributor.authorMulazimoglu, I. E.
dc.contributor.authorOzkan, E.
dc.date.accessioned2020-03-26T17:39:43Z
dc.date.available2020-03-26T17:39:43Z
dc.date.issued2009
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractIn this study, copper(II) and zinc(II) were quantitatively determined in drinking water using ICP-AES after preconcentration. For this purpose, the water samples were treated with 1-nitroso-2-naphthol to form metal complexes on Dowex MWC-1 resin. Prior to the sorption process, the column was treated with a chelating resin Dowex MWC-1 and the column was prepared by passing buffer solution at different pH values. These columns were used for the transportation of water samples through the resin at the flow rate of 2.00 mL min(-1). The effluents were then analyzed by ICP-AES using standard addition method. The effect of pH, amount of resin, ligand concentration and eluent type were investigated. The detection limit for Cu(II) and Zn(II) were found to be 2.78 mu g L-1 and 6.34 mu g L-1 respectively (RSD.'s <%5). It would be concluded that the determination of copper(II) and zinc(II) in drinking water was simple, fast and reliable using this technique.en_US
dc.description.sponsorshipResearch Foundation of Selcuk University, Konya-TurkeySelcuk University [BAP 2003/031]en_US
dc.description.sponsorshipWe thank to the Research Foundation of Selcuk University, Konya-Turkey (BAP 2003/031) for financial support of this work. The study was performed as a part of Ms. Thesis of Aysen Demir Mulazimoglu.en_US
dc.identifier.doi10.1155/2009/734525en_US
dc.identifier.endpage1180en_US
dc.identifier.issn0973-4945en_US
dc.identifier.issue4en_US
dc.identifier.startpage1176en_US
dc.identifier.urihttps://dx.doi.org/10.1155/2009/734525
dc.identifier.urihttps://hdl.handle.net/20.500.12395/23775
dc.identifier.volume6en_US
dc.identifier.wosWOS:000271864800033en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.language.isoenen_US
dc.publisherHINDAWI LTDen_US
dc.relation.ispartofE-JOURNAL OF CHEMISTRYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subject1-Nitroso-2-naphtholen_US
dc.subjectPreconcentrationen_US
dc.subjectResinen_US
dc.subjectDowex MWC-1 resinen_US
dc.titlePreconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AESen_US
dc.typeArticleen_US

Dosyalar