Use of fenton's reagent for removal of pesticides from industrial wastewater

Küçük Resim Yok

Tarih

2007

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

We report in this paper the preliminary results obtained during removal of pesticides from industrial wastewater by Fenton's reagent. Fenton process is attractive alternative to conventional oxidation processes in effluent treatment of recalcitrant compounds. The aim of this study is to evaluate the efficiency of fenton process for the reduction of COD in wastewaters from pesticide industry. Several parameters were also studied: dose of Fe+2 and H2O2. The process of pesticide removal from industrial wastewater using Fenton's reaction has been analysed by taking into consideration COD removal. The optimum ratio of [Fe2+] to [H2O2] was 1: 1,56 (mM/mM) at pH 3.0 and room temperature (20°C). 93 % COD removal was achieved when treated wastewater by Fenton's reagent.

Açıklama

7th International Scientific Conference on Modern Management of Mine Producing, Geology and Environmental Protection, SGEM 2007 -- 11 June 2007 through 15 June 2007 -- Albena -- 101475

Anahtar Kelimeler

Chemical oxidation, Fenton's reagent, Pesticide removal

Kaynak

7th International Scientific Conference on Modern Management of Mine Producing, Geology and Environmental Protection, SGEM 2007

WoS Q Değeri

Scopus Q Değeri

N/A

Cilt

Sayı

Künye