Time domain features of heart sounds for determining mechanical valve thrombosis

dc.contributor.authorAltunkaya, Sabri
dc.contributor.authorKara, Sadık
dc.contributor.authorGörmüş, Niyazi
dc.contributor.authorHerdem, Saadetdin
dc.date.accessioned2020-03-26T18:22:23Z
dc.date.available2020-03-26T18:22:23Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractThrombosis of implanted heart valve is a rare but lethal complication for patients with mechanical heart valve. Echocardiogram of mechanical heart valves is necessary to diagnose valve thrombosis definitely. Because of the difficulty in making early diagnosis of thrombosis, and the cost of diagnosis equipment and operators, improving noninvasive, cheap and simple methods to evaluate the functionality of mechanical heart valves are quite significant especially for first step medical center. Because of this, time domain features obtained from auscultation of heart sounds are proposed to evaluate mechanical heart valve thrombosis as a simple method in this chapter. For this aim, heart sounds of one patient with mechanical heart valve thrombosis and five patients with normally functioning mechanical heart valve were recorded. Time domain features of recorded heart sounds, the skewness and kurtosis, were calculated and statistically evaluated using paired and unpaired t-test. As a result, it is clearly seen that the skewness of first heart sound is the most discriminative features (p < 0.01) and it may be used fairly well in differentiating normally functioning mechanical heart valve from malfunctioning mechanical heart valve. © 2011 Springer Science+Business Media B.V.en_US
dc.identifier.doi10.1007/978-94-007-1192-1_15en_US
dc.identifier.endpage181en_US
dc.identifier.isbn9.7894E+12
dc.identifier.issn1876-1100en_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage173en_US
dc.identifier.urihttps://dx.doi.org/10.1007/978-94-007-1192-1_15
dc.identifier.urihttps://hdl.handle.net/20.500.12395/27313
dc.identifier.volume90 LNEEen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.relation.ispartofLecture Notes in Electrical Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectKurtosisen_US
dc.subjectMechanical heart valve soundsen_US
dc.subjectSkewnessen_US
dc.subjectThrombosisen_US
dc.titleTime domain features of heart sounds for determining mechanical valve thrombosisen_US
dc.typeArticleen_US