Normal Koroner Arterlere Sahip Sol Dal Bloklu Hastalarda Egzersiz Ti-201 Spect ve Tc-99m Tetrofosmin Spect Sonuçlarının Karşılaştırılması

dc.contributor.authorTemizhan, Ahmet
dc.contributor.authorTandoğan, İzzet
dc.contributor.authorYetkin, Ertan
dc.contributor.authorNaldöken, Seniha
dc.contributor.authorÇamsarı, Ahmet
dc.contributor.authorDereağzı, Funda
dc.contributor.authorŞaşmaz, Ali
dc.date.accessioned2020-03-26T16:36:42Z
dc.date.available2020-03-26T16:36:42Z
dc.date.issued2001
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractSol dal bloklu hastalarda (LBBB), sol ön inen koroner arter (LAD) sahasında sintigrafık çalışmalarda sıklıkla yalancı pozitif perfüzyon defektleri vardır. Yüksek orandaki yalancı pozitif sonuçlar nedeni ile sintigrafık çalışmaların koroner arter hastalığı tanısı koymadaki değeri kısıtlıdır. Bu çalışmada koroner anjiyografik olarak normal koroner arterlere sahip hastalarda, egzersiz ile yapılan Thallium - 201 single photon emission komputerize tomografi (Tl-201 SPECT) ve Teknesyum 99 m- Tetrofosmin (Tc-99m Tetrofosmin) SPECT sonuçlarını karşılaştırmayı amaçladık. Çalışmaya koroner anjiyograflk olarak normal koroner arterler tespit edilen 66 LBBB 'lı hasta dahil edildi. Tüm hastalara egzersiz ile Tl-201 SPECT ve Tc-99m Tetrofosmin SPECT uygulandı. Tl-201 SPECT ile 33 (%50) hastada yalancı pozitif sonuç elde edilirken, Tc-99m Tetrofosmin ile 31 hastada %47 yalancı pozitif sonuç elde edildi (p0.05). Egzersiz Tl-201 SPECT ve Tc-99m Tetrofosmin SPECT sonuçları birebir karşılaştırıldığında aradaki uyum %97 olarak bulundu. Sonuç olarak normal koroner arterlere sahip LBBB'U hastalarda Tl-201 ve Tc-99m Tetrofosmin SPECT sonuçları arasındaki yalancı pozitif sonuçlar yönünden istatistiksel anlamlı fark yoktur. Bu nedenle LBBB 'de fonksiyonel iskemiye bağlı olduğu düşünülen yalancı pozitif sonuçlan azaltmak amacı ile yeni sintigrafık ajan veya yöntemlerin bulunmasına gerek vardır.en_US
dc.description.abstractPatients with left bundle branch block (LBBB) often have false positive perfusion defects during scintigraphic studies in myocardial wall supplied by left anterior descending (LAD coronary artery. Diagnostic value of scintigraphic studies in patients with LBBB is limited due to high rate of false positive perfusion defects. We aimed to assess and compare the results of exercise Tl-201 Single Photon Emission Computerized Tomography (SPECT) and Tc-99m tetrofosmin SPECT in patients with LBBB and normal coronary arteries. Sixty six patients with LBBB and normal coronary artery proven angiographycally were included in the study. All patients were studied with exercise Tl-201 SPECT and Tc-99m SPECT. in Tl-201 SPECT study, 33 patients (50) had false positive defects in LAD coronary artery area and 31 patients (47%) had also alse positive defects in LAD coronary artery area in Tc-99m SPECT study. The agreement between Tl-201 SPECT and Tc-99m SPECT was found as 97%. in conclusion in patients patients with LBBB there is no statistical signifıcant difference between Tl-201 SPECT and Tc-99m SPECT in respect to false positive perfusion defects. So some new scintigraphic agents and method are needed to be found for lessening the false positive perfusion defects which is thought to be due to functional ischemia in patients with LBBB and normal coronary artery. Key Words: Left bundle branch block, Normal coronary artery, Myocard perfusion scintigraphy.en_US
dc.identifier.citationTemizhan, A., Tandoğan, İ., Yetkin, E., Naldöken, S., Çamsarı, A., Dereağzı, F., Şaşmaz, A., (2000). Normal Koroner Arterlere Sahip Sol Dal Bloklu Hastalarda Egzersiz Ti-201 Spect ve Tc-99m Tetrofosmin Spect Sonuçlarının Karşılaştırılması. MN Kardiyoloji, 8(6), 410-414.
dc.identifier.endpage414en_US
dc.identifier.issn1300-4778en_US
dc.identifier.issue6en_US
dc.identifier.startpage410en_US
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRRNU1qTXo=
dc.identifier.urihttps://hdl.handle.net/20.500.12395/17412
dc.identifier.volume8en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorTemizhan, Ahmet
dc.language.isotren_US
dc.relation.ispartofMN Kardiyolojien_US
dc.relation.publicationcategoryDiğeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectKalp ve Kalp Damar Sistemien_US
dc.titleNormal Koroner Arterlere Sahip Sol Dal Bloklu Hastalarda Egzersiz Ti-201 Spect ve Tc-99m Tetrofosmin Spect Sonuçlarının Karşılaştırılmasıen_US
dc.title.alternativeComparison of the Results of Exercise Ti-201 Spect and Tc-99m Tetrofosmin Spect in Patients With Normal Coronaries and Left Bundle Branch Blocken_US
dc.typeOtheren_US

Dosyalar