Scleral Perforation Complicating Titanium Mesh Plaque in Orbital Blowout Fracture

Yükleniyor...
Küçük Resim

Tarih

2012

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

LIPPINCOTT WILLIAMS & WILKINS

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

A 27-year-old man who underwent a previous reconstruction surgery for left orbital blowout fracture and recent revision surgery for left cicatricial ectropion was admitted to the ophthalmology outpatient clinic with a 20-mm irregular conjunctival and scleral incision in the left eye at the 6-o'clock position. The scleral and conjunctival incisions were repaired, and during the operation, the anterior end of the titanium mesh plate was visible at the inferior orbital rim. The plastic surgery team removed the irritating end of the plate. Obvious adherence of periocular tissues onto the titanium implant and fibrovascular ingrowth through the implant were seen during this operation. The possible mechanism for the misdirection of the anterior end of the implant might be explained by iatrogenic rotation during the revision of the cicatricial ectropion. To the best of our knowledge, this is the first reported case demonstrating scleral incision caused by an orbital titanium implant.

Açıklama

Anahtar Kelimeler

Scleral perforation, orbital implants, orbital floor fracture

Kaynak

JOURNAL OF CRANIOFACIAL SURGERY

WoS Q Değeri