Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Canel, E" seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a p-tert-butylcalix[4]arene-oxacrown-4
    (ELSEVIER SCIENCE BV, 2004) Demirel, A; Dogan, A; Canel, E; Memon, S; Yilmaz, M; Kilic, E
    A hydrogen ion-selective poly(vinyl chloride) (PVC) membrane electrode was developed using p-tert-butylcalix[4]arene-oxacrown-4 as ionophore. Apart from the ionophore, plasticisers and lipophilic anions were blended, in various proportions, with PVC in tetrahydrofurane and n-fixtures so prepared were poured onto glass surfaces to form the membrane. 2-Nitrophenylpentylether has proved to be the best alternative as plasticiser and the lipophilic anions tried have turned out to have an adverse effect on the pH response. The electrode of the optimum characteristics had a composition of 2% p-tert-butylcalix[4]arene-oxacrown-4, 68.3% o-NPPE and 29.7% PVC. The electrode showed an apparent Nernstian response in the pH range 2-11 with a slope of 54.2 +/- 0.4 mV pH(- 1) at 20 +/- 1 degreesC. It has a rapid potential-response to changes of pH, high ion selectivity towards lithium, sodium and potassium, and other characteristics comparable to those reported for the conventional pH glass membrane electrode. It appears to be a suitable potentiometric indicator electrode specifically for hydrofluoric acid solutions. (C) 2003 Elsevier B.V. All rights reserved.
  • Küçük Resim Yok
    Öğe
    Using of hydrogen ion-selective poly(vinyl chloride) membrane electrode based on calix[4]arene as thiocyanate ion-selective electrode
    (ELSEVIER SCIENCE SA, 2006) Erden, S; Demirel, A; Memon, S; Yilmaz, M; Canel, E; Kilic, E
    A hydrogen ion-selective electrode (ISE) is prepared by using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanometoxy-calix[4]arene and an investigation about whether it could be used as a thiocyanate ion-selective electrode is made by using its characteristic of becoming thiocyanate sensitive in acidic regions. The electrode of the optimum characteristic has a composition of 1% ionophore. 66% 2-NPOE and 33% poly(vinyl chloride) (PVC). This electrode exhibits a linear response over the range 1.0 x 10(-1) to 3.0 x 10(5) M of thiocyanate with a slope of 52.0 +/- 0.2 mV/pSCN. The effects of the pH and the membrane composition are also investigated. The lifetime of the electrode is at least 4 months and its response time is found to be 10-15 s. The selectivity coefficients of some anions are calculated by using mixed solution interference method. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported. There is a good agreement between the results obtained by the proposed electrode and the Mohr method at 955 confidence level. (c) 2005 Elsevier B.V. All rights reserved.

| Selçuk Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Selçuk Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Konya, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim